Here are the latest updates for TAP, Revision 5.3:

NEWEST FEATURES and FIXES

  • Fix interim setpoint calculation for PID period other than 4

Here are the latest updates for TAP, Revision 5.2:

NEWEST FEATURES and FIXES

  • Fix Salt Bath Firing Mode bug
  • Fix Relay Actuation double counting bug

Here are the latest updates for TAP, Revision 5.1:

NEWEST FEATURES and FIXES

  • Add Simple Setpoint Firing Mode
  • Remove delay start from New Schedule, Edit Schedule, and Schedule Summary
  • Add Advanced Network Settings for Future Use
  • Eliminate ability to rollback to versions prior to 5.0

Here are the latest updates for TAP, Revision 5.0:

NEWEST FEATURES and FIXES

  • Convert settings from CSV to Key-Value Pairs
  • Update Default Configuration Splash Screen Styling
  • Offload Logs to USB from Event Logs
  • Add Advanced Settings for PID
  • Add Advanced Settings for Zone Control
  • Add Advanced Settings for Copy Schedules
  • Bug Fix for indefinite hold while ramping down at controlled rate
  • Bug Fix for Celsius Ramp Rate conversion

Here are the latest updates for TAP, Revision 4.4:

  • Bug Fixes

Here are the latest updates for TAP, Revision 4.3:

  • Bug Fix for Auxiliary Output Enable

Here are the latest updates for TAP, Revision 4.2:

NEWEST FEATURES

  • Provide push notifications when diagnostics thresholds are met
  • Bug Fix for automatic software download
  • Bug Fix for Ramp Rate Regular Expression

Here are the latest updates for TAP, Revision 4.1:

NEWEST FEATURES

  • Incorporate ability to remotely view active Firing Log
  • Allow for remote Skip Step and remote Abort Firing
  • Allow for remote schedule editing while in Standby or Execute mode
  • Incorporate ability for remote clearing of Error Log, Firing Log, and Diagnostics
  • Allow for remote schedule creation

Here are the latest updates for TAP, Revision 4.0:

NEWEST FEATURES

  • Settings, Diagnostics, Error Log, and Firing Logs pushed to TAP Servers for remote viewing via TAP Mobile
  • Skip Delay Start after beginning a Firing
  • Stop resetting delay start when editing a firing schedule
  • Correct Relay Actuations and Element On Time updates to diagnostics
  • Independent Control, Monitoring, and Networking threads

Here are the newest features and enhancements for TAP, Revision 2.6:

NEWEST FEATURES

  • Allow cancellation of New Segment entry when creating a new schedule or editing an existing schedule
  • Incorporate a programmable thermocouple offset
  • Automatically fetch software updates from the SDS Industries SW Update repository and notify users when available (Requires Network Connection)
  • Dual Mode configuration – Control certain output channels depending on programmed advanced settings and selected fire mode
  • Favorites tab on schedules. Double click schedule title to add to favorites for quicker access to the most used schedules in the future
  • Enable networking page. Establish wired network connection. Enable transmission of kiln data to SDS Industries server for use with mobile application


ENHANCEMENTS

  • Limit Logs to 1000 entries for better performance
  • Add countdown to touchscreen calibration
  • Added settings page to allow reset of date and time without needing to reboot the controller
  • Updated the firing log sort, in descending order, by standardizing the format of firing log titles
  • Provide delay start countdown to program execution page
  • Reduce overshoot when firing AFAP


BUG FIXES

  • Correct Preventative Maintenance notifications
  • Correct inconsistent display of 9999 v. AFAP in New Schedule, Edit Schedule, and Execution
  • Incorporate enhanced error checking for ramp rates exceeding kiln capability (reduces chance of “Kiln is failing to heat for too long” alarm and unnecessary program abort)
  • Update cost page to provide standard formatting
  • Correct programmable delay start values to 0-2880 minutes
  • Correct calculation of interim setpoints after editing current step of execution